JETmaster / 24 bis 240 Zonen

JETmaster TP – up to 240 zones from a standing start

The main features in brief:

  • Extended mould diagnosis
  • For 24 to 240 zones in steps of 8
  • 230V / 16A per zone
  • Industrial PC with 15” touch panel
  • Software updates per download

When you need that little bit of extra in terms of performance

Up to 240 zones on four wheels with maximum operating comfort: Clear touch panel and maximum data compatibility – this “control cabinet” is where it’s at! The JETmaster TP, the floor-mounted device from our systematic TP series, combines all the requirements for optimum process reliability and ease of use in one device. Once connected, all moulds are immediately operational again without the need for a restart. Comfortable: the control via industrial PC with large touch panel. Profitable: Maximum-sized external cooling elements ensure that the device remains maintenance- and wear-free.


Technical specifications

Housing:

aluminium, color RAL 5010 gentian blue,

Special color on request


Dimensions:

See table "Device versions"


Temperature control:

microprocessor-controlled multi-channel controller

with automatic calculation of

Control parameters individually for each zone


Operation/Visualization:

Industrial PC with 15" touch panel


sensor input:

Thermocouple Fe/CuNi, switchable to

Ni/CrNi with internal comparison measuring point


Temperature range:

0-500°C, switchable to 32-932°F


calibration accuracy:

≤ 0,25 %


Heater outputs:

230 VAC/16 A = 3680 W per zone, fail-safe algorithm, protected with high-speed fuses FF 16 A, 6.3 x 32 mm


Alarm output:

Potential-free alarm contact, loadable up to

max. 250 VAC/2 A (invertierbar)


Safety shutdown:

load shedding with a broken triac (short circuit)


Reduction/Boost:

can be switched manually and externally via 24 V DC


Mould connection:

customized


Power supply:

400 VAC +10...-10 %, 50...60 Hz, 3P/N/PE,

other voltages on request


Mains connection:

CEE 32 A, CEE 63 A, CEE 125 A,

Multiple feed, attachment plug


Interfaces:

1x USB-extern, 1x Ethernet, OPC/UA, optional RS232,

RS485, TTY


Control fuse:

Fuse MT 6.3 A, 5 x 20 mm


Ambient temperature:

Operation 0… 50° C, storage -30… 70° C


Climatic application class:

according to DIN 40 040, relative humidity ≤ 75% im

Annual mean, no condensation


Protective system:

  • IP20


Protection class:

  • I



User interface:


Industrial PC with 15“ touch panel, optionally with offset screen. The JETmaster TP is fanless and maintenance-free.


  1. Industrial PC with 15” touch panel
  2. Fuses

Device rear view:


All device data and mould settings can be centrally stored and managed via the Ethernet connection. We will manufacture the mould and network connections according to your individual company standards.


  1. Ethernet connection for NVS and DMS
  2. Mould connection – custom-made for you
  3. Power supply – custom-made for you
  4. Alarm contact
  5. Reduction and boost
  6. Power switch  

Possible combinations:


All device data and mould settings can be centrally stored and managed via the Ethernet connection. Furthermore, additional devices such as needle valve-control NVS and pressure measuring system DMS are linked with the devices via the Ethernet connection. These then perform the operation and visualisation. Various injection moulding machines can be connected via conventional data interfaces or via the Ethernet so that operation and visualisation occurs on the machine’s screen.

Share by: